What do termites do to the foam?
EPS pro­vides no nutri­ent val­ue and is not a food source for ter­mites. If left exposed, ter­mites may tun­nel into the foam in search of fibrous food. When build­ing, in a heavy ter­mite infes­ta­tion area, care is required in the detail­ing and con­struc­tion of the walls that will be in con­tact with ground, to pre­vent access to the foam for ter­mites.
Is an ICF home quieter than a stick framed home?
Absolute­ly. The exte­ri­or walls are two lay­ers of con­tin­u­ous insu­la­tion, the den­si­ty of sol­id con­crete and a lay­er of ½” gyp­sum board on the inside all con­tribute to supe­ri­or sound sup­pres­sion of STC 50 for the whole build­ing enve­lope. Note: A wood frame sys­tem of equiv­a­lent STC rat­ing would be 2 x 4 studs spaced 16˝ o/​c, with 3½˝ absorp­tive mate­r­i­al, 1 lay­er of 5 /8˝ Type X gyp­sum board on resilient chan­nels spaced 16˝ o/​c, and 2 lay­ers of 5 /8˝ Type X gyp­sum board on the oth­er side. (Cour­tesy of 1995 NBCC Sec­tion A9.10.3.1 Wall #W5a)
How do I determine which size ICF to use?

ICFs pro­vide a rein­forced con­crete wall which is designed to spe­cif­ic engi­neer­ing prin­ci­ples. Typ­i­cal res­i­den­tial con­struc­tion, per the applic­a­bil­i­ty lim­its in the build­ing code, allows walls 10′ (3 m) high or less between lat­er­al sup­ports (floor and roof con­nec­tions). Below grade walls must have a min­i­mum 6″ (150 mm) con­crete core. In some regions, an 8″ (200 mm) con­crete core is the min­i­mum allowed thick­ness for below grade walls.

The 4″ (100 mm) form can­not be used below grade as a foun­da­tion wall. The 4″ (100 mm) form may be used for above grade walls up to a max­i­mum of 10′ (3.0 m).

The 6″ (150 mm) form, above grade, is lim­it­ed to approx­i­mate­ly 14′ (4.2 m) in height. Walls high­er than 14′ (4.2 m) must use an 8″ (200 mm) or larg­er form.

Typ­i­cal res­i­den­tial con­struc­tion will use 6″ or 8″ con­crete core size blocks. Project spe­cif­ic engi­neer­ing may allow for some core thick­ness to span ver­ti­cal­ly high­er than these pro­posed guide­lines.

What is EPS made from?
Poly­styrene is vir­gin mate­r­i­al, man­u­fac­tured from petro­le­um. Poly­styrene beads are expand­ed with steam heat to be up to 40 times their orig­i­nal vol­ume and then the expand­ed beads are mold­ed again by steam heat into 258″ rigid insu­la­tion pan­els to cre­ate a Fox Blocks ICF.
How much will it cost per square foot to build an Fox Blocks ICF home?

Build­ing with Fox Blocks ICFs pro­vides you with a high per­for­mance wall sys­tem for the foun­da­tion and above grade walls. Build­ing any high per­for­mance home, with either ICFs or con­ven­tion­al wood fram­ing, has many fac­tors that define the end cap­i­tal costs.

What addi­tion­al mate­ri­als and labor are required to make a con­ven­tion­al foun­da­tion equiv­a­lent to an Fox Blocks ICF foun­da­tion which exceeds ener­gy code require­ments in most loca­tions? Con­ven­tion­al wood fram­ing requires con­sid­er­ably more mate­r­i­al, insu­la­tion and atten­tion to air seal­ing to make it qual­i­fy and per­form as a high per­for­mance wall. All of this, for con­ven­tion­al con­struc­tion, adds mate­r­i­al and labor costs to the over­all project. Fox Blocks ICFs pro­vide a sim­ple method to build high per­for­mance walls that pro­vide ongo­ing ben­e­fits from the high insu­la­tion val­ues and mass con­crete walls that are ener­gy-effi­cient and pro­vide cost sav­ings for the life cycle of the build­ing.

Com­par­ing cost per square foot between con­ven­tion­al con­struc­tion and ICFs for a high per­for­mance build­ing, is like com­par­ing apples to oranges. To devel­op con­struc­tion costs, more detailed infor­ma­tion is required, for instance the num­ber and size of open­ings, the shape and size of the home, the region­al costs for mate­r­i­al and labor, etc. If you have a project you’d like us to review and pro­vide a mate­r­i­al esti­mate, Fox Blocks would be hap­py to have one of our rep­re­sen­ta­tives con­tact you. Please com­plete and sub­mit a lead infor­ma­tion sheet on the web­site or call Cus­tomer Ser­vice.

How do frame in openings?
Fox Blocks has devel­oped the Fox Buck specif­i­cal­ly to frame open­ings such as win­dows and doors. The Fox Buck pro­vides insu­la­tion around the open­ing plus sup­port for the attach­ment of the win­dow or door.
What is the difference between Fox Blocks ICFs and the competitors, and why are Fox Blocks ICFs better? Why should I use Fox Blocks ICFs?
Most ICF blocks share com­mon fea­tures and ben­e­fits. Fox Blocks, as a com­pa­ny, pro­vides 30 years’ expe­ri­ence in prod­uct devel­op­ment, doc­u­men­ta­tion, test­ing and train­ing, as well as ver­sa­til­i­ty in the line of prod­ucts to meet all appli­ca­tions. The key dif­fer­ence comes in the exper­tise and sup­port you get from Fox Blocks. Fox Blocks is the leader in insu­lat­ing con­crete form con­struc­tion – proven in over 100,000 com­mer­cial and res­i­den­tial projects across North Amer­i­ca. Exten­sive resources and sup­port sys­tems are avail­able to ensure your project’s suc­cess from start to fin­ish. Please vis­it our web­site www.Fox Blocks​.com to review our project gallery and find more detailed doc­u­men­ta­tion on the prod­ucts and the appli­ca­tions. Fox Blocks also pro­vides a toll free num­ber for Cus­tomer and Tech­ni­cal Sup­port 8773692562.
How do I apply traditional stucco to an ICF?

Tra­di­tion­al stuc­co has a thick cemen­ti­tious base, typ­i­cal­ly installed over a met­al lath. The met­al lath is fas­tened direct­ly to the Fox Blocks webs with screw or sta­ples.

How do you control voids in the wall?
The con­crete mix is a high slump 5″- 6.5″ (125 mm – 165 mm) with a small­er aggre­gate size so the con­crete flows eas­i­ly. The per­son in charge of plac­ing the con­crete should watch the con­crete flow through­out the whole wall to ensure there are no void pock­ets. Inter­nal vibrat­ing pro­vides good con­sol­i­da­tion, elim­i­nat­ing voids.
Is there a top and bottom on the blocks when installing the Fox Blocks forms?
Fox Blocks forms have a reversible inter­lock sys­tem on all blocks. The robust inter­lock allows the blocks to fit togeth­er very tight­ly, elim­i­nat­ing any require­ment for adhe­sives. A reversible inter­lock speeds up the instal­la­tion.