What fasteners are recommended for ICFs?
Fox Blocks has conducted numerous fastener tests for pull-out strength and shear capacity for various fasteners – screws, ring shank nails and staples into the plastic webs. The recommendation for interior and exterior applications of finish materials is for the use of screws which provide the best holding capacity into the plastic webs or fastening strips in the forms which are identified on each block.
The EPS insulation does not provide any holding capacity for fasteners.
Do ICFs require a special concrete mix design?
The concrete is normal strength, minimum 2500 psi (20 MPa) per building codes. The mix design specifies a smaller aggregate and higher slump than concrete typically used for floors. Most Ready-Mix suppliers are familiar with an ICF concrete mix design.
Is there a problem when placing concrete, dropping concrete from the top of the wall which may be over 8' (2.4 m)?
No. Specifications in the America Concrete Institute (ACI) do not limit the maximum distance concrete can free fall. Engineering studies and reports have shown that free fall from up to 35′ doesn’t reduce concrete quality and there is no evidence of segregation or weakened concrete strength. ICF concrete design calls for a high slump mix which assists in reducing segregation.