Is installing ICFs a DIY project?
Fox Blocks rec­om­mends that all installers using Fox Blocks ICFs com­plete a Fox Blocks train­ing pro­gram to ensure they have a bet­ter under­stand­ing of the basics. How­ev­er, for first time installers, it is pre­ferred that a Fox Blocks trained, expe­ri­enced installer inspect the instal­la­tion pri­or to place­ment of con­crete and assist in the place­ment of the con­crete, as they are famil­iar with work­ing with con­crete and can ensure the build is struc­tural­ly sound and safe and the walls are con­sol­i­dat­ed prop­er­ly, built straight and plumb.
What is a ‘blow-out’?

A blow-out’ is a break in the form, gen­er­al­ly due to the pres­sure from the liq­uid con­crete dur­ing the con­crete place­ment and/​or con­sol­i­da­tion. Fox Blocks ICFs are designed to main­tain a high safe­ty fac­tor of pres­sure from the liq­uid con­crete. Dam­aged forms or fail­ure to sup­port areas where forms have been cut leav­ing a large area of EPS between the web sup­ports may cause a blow-out. Over con­sol­i­da­tion may also cause a blow-out.

Fox Blocks rec­om­mends the Pre-Place­ment Check­list be reviewed for all wall assem­blies pri­or to the place­ment of con­crete, to find poten­tial prob­lem areas and install addi­tion­al strap­ping or sup­port to pre­vent blow-outs. Gen­er­al­ly, for an Fox Blocks form, the size of a blow-out may be lim­it­ed to the EPS between the webs, 6″ or 8″ wide by the height of one form. If a blow-out occurs, the con­crete pour moves to anoth­er area on the wall, the hole is patched by replac­ing the EPS, installing wood sup­port over the area, and then resum­ing the pour.